Can a pilot light get clogged

The pilot light may be going out if the pilot tube (burner) is blocked, dirty, or clogged. A dirty pilot tube will not be as reliable than if it is clean. … Any blockage in the pilot tube will cause the furnace to not stay lit. So cleaning it is an easy solution without having to replace any parts.

How do I clean the thermocouple on my propane fireplace?

  1. Turn off the fireplace gas valve and remove the front panel from the fireplace. …
  2. Find the thermocouple, which is located next to the pilot light and looks like a small straight pipe.
  3. Use a can of compressed air to gently blow away any dust and dirt from the thermocouple.

Why is my pilot light yellow?

The most common reason why a pilot light would start to burn yellow is that the air intake valve to the pilot light is clogged with dirt. … If there is a small amount of dirt blocking the air, the yellow color might only be at the tip of the flame. If there is a large amount of dirt, the entire flame will burn yellow.

What does it mean when your pilot light won't stay lit?

If your pilot light won’t stay alight, it might be the thermocouple. Sometimes dust buildup collects on the thermocouple and blocks the sensor. Try cleaning the thermocouple and then relighting the pilot light. If it continues to go out, the thermocouple might need to be replaced.

How do you clean a dirty thermocouple?

The best way to clean your thermocouple is to use either a piece of steel wool or the coarse side of a sponge to gently clean off any soot or other remnants. You can use a pencil eraser to clean between the threads of the screw that connects the thermocouple to the control valve of your system.

Why does my gas pilot light keep going out?

A faulty, misaligned, dirty, or damaged thermocouple is often the culprit behind your pilot light going out. The thermocouple is an automatic safety shutoff device that prevents the gas valve from opening if the pilot light is out.

What's a thermocouple look like?

The thermocouple looks like a piece of metal tubing smaller than a soda straw. To find it, first locate the gas control box. This is the box that the main gas line enters, where you turn the gas on in the furnace. (On most furnaces, it also houses the button that you hold open or push to relight the pilot.)

Can you clean a thermocouple?

Yes, you can clean a thermocouple, but the task must be done with a light touch. Remove the thermocouple from the process assembly, using a steel wool or emery cloth, lightly clean the tip removing any build up.

How do I know if my thermocouple is bad on my gas fireplace?

The Fix: Pilot Light to Gas Fireplace Won’t Stay Lit So you’ve checked your pilot light and even reset it, but still, it wont stay lit. This can be an indication that your fireplace thermocouple is either bad or worn out.

Should I turn off the pilot light on my gas fireplace in the summer?

Your Utility Bill Perhaps the most important reason to turn off gas fireplace pilot light in summer is because of the money and energy you will be saving. If you leave the pilot light on during the summer it is simply sitting there burning gas, which is wasting gas and contributing to an exorbitant energy bill.

Article first time published on

How do you remove a thermocouple from a gas fireplace?

The only tool you need to replace a thermocouple is a wrench. Turn off the gas supply to the gas valve. Use the wrench to unscrew the connector that holds the thermocouple to the gas valve, then unhook the probe from its clip and pull out the entire thermocouple assembly.

How do you know if you have a bad thermocouple?

If you can’t get the flame to light at all, and you’re sure the gas is on, there’s probably an obstruction in the pilot tube. If the flame lights and goes out when you release the gas control knob after holding it in for the recommended 20 to 30 seconds, that’s the sign of a thermocouple malfunction.

How much does it cost to replace a thermocouple?

It costs $150 to $250 to replace a thermocouple. It checks to make sure the pilot light is on. It will shut the gas off if it’s not.

Why won't my pilot light stay lit on my propane heater?

If the thermocouple is too far from the flame, this can cause the pilot to go out and shut down the propane heater; you can fix this easily by moving the thermocouple closer to the flame. The thermocouple could also be worn out, in which case it needs to be replaced.

How do you fix a yellow flame on a gas fireplace?

Make Sure the Damper is Open By opening the damper to the fireplace, you are allowing proper ventilation. This will control the color of the flame. To adjust it so that the flames have an orange or yellow tip to them, lower the air input. You can do this by changing the damper or by closing the air shutter.

What color should a propane pilot light be?

Inspecting a Gas Furnace Pilot Light Flame The first thing to check is the color of the flame. A natural gas flame should be a bright blue color with a small amount of yellow at the very tip. A propane flame will have more of a bluish-green flame with a tinge of yellow at the tip.

What color should the pilot be on a gas fireplace?

The color of the pilot light should be blue because that means that only natural gas—without any other condensates—is reaching the pilot light through the gas main. The principal chemical compound found in natural gas is methane, and methane burns blue.

Can I use sandpaper to clean a thermocouple?

Cleaning the thermocouple You can use Emery cloth sandpaper to gently clean any debris or build-up from the end of the thermocouple. … Be aware, you may need to detach the thermocouple from the burner assembly to clean it thoroughly. Use a lint-free cloth to wipe the component clean of any remaining debris.

How long does a fireplace thermocouple last?

Thermocouples can last up to 10 years if properly installed and maintained, while furnaces can last 15-20 years, although either may wear out sooner in multifamily units.

Can I replace a thermocouple myself?

The No. 1 cause of pilot lights that won’t stay lit is a worn-out thermocouple. It’s easy to replace and a new one costs $5 to $10. Rather than trying to unfasten the thermocouple inside the water heater’s burning chamber, it’s easier to remove the whole burner and thermocouple assembly.

Do Thermopiles go bad?

Like the other component parts in your furnace, the thermocouple can wear down over time, producing lower voltage than it should when heated. And the worst part is that you can have a bad thermocouple without even knowing. Therefore, inspecting and testing your thermocouple should be part of your furnace maintenance.

How do you bypass a thermocouple?

  1. Move the tilts switch wire aside.
  2. Remove your thermocouple from the heater using an 8mm wrench.
  3. Pull the valve housing aside using your 13mm socket wrench. …
  4. Remove the valve using your pliers. …
  5. Put your thermocouple back into position.

Should a pilot light always be on?

Generally speaking, it is safe to leave your continuous pilot light on at all times, assuming it stays lit (more on this in a moment). While it does cost more to keep your pilot light on in between uses, it can actually have some benefits to your system.

How do you manually turn on a gas fireplace?

Turn the knob from the “Off” to the “Pilot” position. Push in the pilot knob, which manually sends gas into the system. Push the igniter button once every second until it lights. Depending on how long it’s been since the gas fireplace was last used, ignition may take multiple attempts.

What causes a thermocouple to go bad?

Changes in temperature can cause regular expansion and contraction in metal, which will cause thermocouples to weaken over time. After enough time, metal fatigue can cause a thermocouple to break. … If thermocouples start to give out unusual readings, it may be suffering from metal fatigue.

What can go wrong with a thermocouple?

  • Gas flow. The thermocouple may be hampered by a clog in the gas line or some other issue which prevents the gas from reaching it. …
  • Sudden loss of heat. …
  • Loose wires.

Are thermocouples universal?

Honeywell, White Rodgers, and other manufacturers make universal replacement thermocouples, usually with a 30-millivolts (mV) rating for standing-pilot furnaces. … Electronic flame sensors are much less universal, and you must find the exact part specified for your furnace model.

What does a thermocouple do in a gas fireplace?

Any gas appliance with a standing pilot needs a thermocouple to keep the pilot lit, whether it cycles on and off automatically, like a water heater, or you operate it manually, like a gas fireplace. The function of the thermocouple is to send a signal to the gas valve to stay open while the pilot is on.